Epoxy-Coated Bolted Tanks
Describe Epoxy-Coated Bolted Tanks are modular steel storage systems protected by high-performance……

Describe

Epoxy-Coated Bolted Tanks are modular steel storage systems protected by high-performance epoxy coating applied to prefabricated steel panels. This coating system provides reliable corrosion protection for mild to moderate service environments while offering a cost-effective alternative within the Bolted Tanks product family.

As a complementary solution to Glass-Fused-to-Steel tanks, Epoxy Bolted Tanks are widely used in municipal and industrial projects where controlled operating conditions, fast installation, and optimized project budgets are key considerations.

Key Engineering Advantages

  • High-Performance Epoxy Coating
  • Provides effective corrosion resistance for defined service conditions.
  • Cost-Optimized Solution
  • Lower initial investment compared with glass-lined systems.
  • Modular Bolted Construction
  • Rapid on-site assembly and flexible capacity adjustment.
  • Smooth Internal Surface
  • Reduces sediment buildup and simplifies cleaning.
  • Factory-Applied Coating
  • Ensures consistent coating thickness and quality control.
  • Ease of Maintenance
  • Localized repair possible without full recoating.

Typical Storage Media

Epoxy-Coated Bolted Tanks are suitable for:

  • Industrial process water
  • Cooling water and utility water
  • Treated wastewater and effluent
  • Non-aggressive industrial liquids
  • Intermediate storage applications

Epoxy Coating System

The epoxy coating is applied to steel panels under controlled factory conditions using advanced spray or roller coating processes, followed by curing to achieve strong adhesion and uniform film thickness. The coating system is selected based on project requirements, including liquid type, temperature, and corrosion class.

Key coating characteristics include:

  • Good chemical resistance within specified limits
  • Strong adhesion to steel substrate
  • Smooth and hygienic surface
  • Compliance with relevant industrial coating standards

Standard Technical Specifications

Item Specification Range
Tank Diameter 3 m – 50 m
Tank Height 3 m – 20 m
Storage Capacity 50 m³ – 80,000 m³
Panel Thickness 3 mm – 10 mm
Steel Grade Q235B / Q345B or equivalent
Coating Type High-performance epoxy
Coating Thickness 300 – 500 μm (system dependent)
Connection Type High-strength bolted connection
Sealing Material EPDM / NBR
Design Standard AWWA D103, ISO, EN standards
Wind Load Project-specific design
Seismic Design Available per seismic zone
Operating Temperature -20°C to +70°C
Expected Service Life 15–25 years (design dependent)

Engineering & Supply Scope

  • Tank structural design and coating selection
  • Panel fabrication and epoxy coating
  • Roof systems and accessories supply
  • On-site installation supervision or full installation service
  • Inspection, testing, and commissioning support

Quality Control & Standards

Epoxy-Coated Bolted Tanks are manufactured under strict quality management systems covering material traceability, surface preparation, coating application, and final inspection. Coating performance and structural integrity are verified prior to shipment.

Share your storage medium, capacity, and operating conditions. Our engineers will recommend a suitable epoxy bolted tank configuration.